In accordance with our policy to continually improve products based upon changes in technology, Tokistar Lighting reserves the right to vary product specifications without prior notice.
Mounting Channels and Lens Covers are extruded polycarbonate with a flammability rating of UL 94-V0.
Series AVO tube guards have a flammability rating of UL 94-V0 and conform to UL Standard 746C for exposure to ultraviolet light and water absorption.
Ratings are based upon the manufacturer’s published life data. Life of xenon sources is determined by the industry standard Mean Time Before Failure (MTBF) method, defined as the time when 50% of lamps fail. With our LED source, life is defined as the time when lumen output depreciates to 70% of its initial value. Actual lifetime may vary based upon environmental conditions
Advantage Lighting Systems are ETL Listed
Each Advantage socket is provided with four mounting holes. For secure mounting, use two screws in opposing holes.
Advantage fixtures are flexible enough to turn corners without the use of special hardware, eliminating any dark spots at corner locations.
Attach the mounting channel securely in place with screws. Insert one side of socket under the lip of the mounting channel, then snap the socket in place.
The mounting channel is flexible in one direction and will conform to a 24” radius with lamps facing into or away from the bend.
Xenon lamps produce heat and will cause damage if they come in direct contact with persons or combustible materials. If fixtures are positioned where these conditions can occur, Advantage should always be specified with the appropriate lens cover to prevent harm.
In accordance with NEC/NFPA 70 Article 410.11, combustible materials next to the fixtures must not be subjected to temperatures in excess of 90º C (194º F). In order to conform to this standard, fixtures need to be installed according to the minimum space requirements shown below.
Advantage xenon lamps may be operated from magnetic or electronic transformers. The transformers featured in our catalog are fully dimmable with the appropriate style of dimmer suitable for use with magnetic or electronic transformers.
Tokistar's LED modules are suitable for use with a wide range of industry-standard dimmers. There are some compatibility issues with certain models.
Following these guidelines should ensure proper dimming of our lighting system, but we cannot test our product with every make and model number. To confirm there is no issue with compatibility:
Catalog #: AV-3-X5
Test Criteria: Lamps: 5 Watt/40 Lumen; Spacing: 3” O.C.; Fixture length: 48”
Conversion Factors
Lamps:
3 Watt/12.5 Lumen X3, Multiply by 0.31
8.5 Watt/70 Lumen X8, Multiply by 1.75
5 Watt/20 Lumen X5B, Multiply by 0.50
8.5 Watt/40 Lumen X8B, Multiply by 1
Spacing:
2.4” O.C., Multiply by 1.25
4.0” O.C., Multiply by 0.75
6.0” O.C., Multiply by 0.50
Catalog #: AV-3-X5-AR
Test Criteria: Lamps: 5 Watt/40 Lumen; Spacing: 3” O.C.; Fixture length: 48”
Conversion Factors
Lamps:
3 Watt/12.5 Lumen X3, Multiply by 0.31
8.5 Watt/70 Lumen X8, Multiply by 1.75
5 Watt/20 Lumen X5B, Multiply by 0.50
8.5 Watt/40 Lumen X8B, Multiply by 1
Spacing:
2.4” O.C., Multiply by 1.25
4.0” O.C., Multiply by 0.75
6.0” O.C., Multiply by 0.50
Catalog #: AV-3-X5-AR
Test Criteria: Lamps: 5 Watt/40 Lumen; Spacing: 3” O.C.; Fixture length: 48”
Conversion Factors
Lamps:
3 Watt/12.5 Lumen X3, Multiply by 0.31
8.5 Watt/70 Lumen X8, Multiply by 1.75
5 Watt/20 Lumen X5B, Multiply by 0.50
8.5 Watt/40 Lumen X8B, Multiply by 1
Spacing:
2.4” O.C., Multiply by 1.25
4.0” O.C., Multiply by 0.75
6.0” O.C., Multiply by 0.50
Catalog #: AV-3-LWW
Test Criteria: 0.72 Watt 2400K LED/21 Lumen; Spacing: 3” O.C.; Fixture length: 48”
Conversion Factors
Light Source:
0.72 Watt 3000K LED/24 Lumen, Multiply 1.14
Spacing:
2.4” O.C., Multiply by 1.25
4.0” O.C., Multiply by 0.75
6.0” O.C., Multiply by 0.50
Catalog #: AVO-3-X5
Test Criteria: Lamps: 5 Watt/40 Lumen; Spacing: 3” O.C.; Fixture length: 48”
Conversion Factors
Light Source:
3 Watt/12.5 Lumen X3, Multiply by 0.31
LED: Refer to LED Graph
Spacing:
4.0” O.C., Multiply by 0.75
6.0” O.C., Multiply by 0.50
AVLC-WH-3-X5
Test Criteria: Lamps: 5 Watt/40 Lumen; Spacing: 3” O.C.; Fixture length: 48”
Conversion Factors
Light Source:
3 Watt/12.5 Lumen X3, Multiply by 0.31
LED: Refer to LED Graph
Spacing:
4.0” O.C., Multiply by 0.75
6.0” O.C., Multiply by 0.50
AVCC-WH-3-X5
Test Criteria: Lamps: 5 Watt/40 Lumen; Spacing: 3” O.C.; Fixture length: 48”
Conversion Factors
Light Source:
3 Watt/12.5 Lumen X3, Multiply by 0.31
LED: Refer to LED Graph
Spacing:
4.0” O.C., Multiply by 0.75
6.0” O.C., Multiply by 0.50
The sections below show typical point-by-point footcandle values for three typical applications.
Overhang
Surface reflectance: 50%
Cove
Surface reflectance: 80%
Under Cabinet
Surface reflectance: 50%
Photometrics by Tokyo Metropolitan Industrial Technology Research Institute (Tokyo, Japan). Testing conducted in accordance with current IES published procedures.