Maximum Run Lengths
To minimize voltage drop and keep conductors safely within their rating, do not exceed
the maximum lengths shown for each independent Cable Lighting fixture.
Cable Lighting Systems are ETL Listed and bear the CE Mark for conformance to European Standards.
This proprietary Dimming System provides full-range dimming of Cable Lighting LEDs. The system components connect with CAT5 cable. Up to 25 dimmer packs may be connected in series if the total length of all CAT5 cable does not exceed 165 feet from the wall dimmer to the last dimmer pack. CAT5 cables are included with units.
Wall Dimmer (Part #: LC-DMR)
The remote wall dimmer has a rotary dial and on/off switch. Power to the wall dimmer is provided from the LED Driver powering the first Dimmer Pack.
Dimmer Pack (Part #: LC-1CH-DP)
Each dimmer pack receives an 8 VDC input from an LDR8-40 LED Driver and sends a 0-8 VDC output to the fixture. Logic input and output is communicated through CAT5 Cable.
Dimensions: 1-1/2” x 3-1/2” x 4-1/16”
Tokistar's LC-1CH-MULTI Dimmer Pack is compatible with industry-standard dimmers working on DMX or 0/1-10 VDC protocol. In the manual mode, a preset light level can be set without the use of any external dimmer.
Part #: LC-1CH-MULTI
Technical Specifications:
Max. Load: 40 Watts @ 8 VDC
Environmental Rating: Dry Location/IP20
Dimensions: 3/4” x 1-3/4” x 3-1/2”
Weight: 50g / 0.11 lbs
Listing: ETL Listed/CE Certified
Operating Temperature: 0~+50ºC
DMX Mode
In this mode, dimmer packs are addressable and may be used with any controller working on DMX protocol. Up to 36 dimmer packs may be connected in series. For applications exceeding 36 dimmer packs, an additional feed from the DMX dimmer is required. The additional feed(s) can be sent directly from the dimmer, or you may specify DMX Splitters. Consult factory on details of DMX Splitters.
Analog Mode 0/1-10VDC
For operation from devices using 0/1-10VDC protocol, up to 10 dimmer packs may be connected in series. For applications exceeding 10 dimmer packs, an additional feed from the analog dimming device is required.
Manual Mode
You may select a light intensity at which the fixtures operate. In this case, no external dimming device is required.