LED Driver LDR8-40
Tokistar’s LDR8-40 is a 40 Watt UL Recognized Class 2 LED Driver used to convert an AC input into an 8 VDC output. It may be operated from a wide range of input voltages. The enclosure is suitable for wet locations.

Part #: LDR8-40

Specifications
Input Range: 100-240 VAC
Frequency Range: 50/60 Hz
Output: 8 VDC (Adjustable +10% / -25%)
Max. Output Current: 5.0A
Max. Output Power: 40W
Protection: Overload, Overcurrent, Short Circuit
Operating Temperature: -30ºC to +60ºC
Mechanical Specifications
Dimensions: 3” x 9.75” x 2”
Weight: 1.94 lbs
Enclosure Rating: Nema 3/IP65
Mounting: Flange Mount
Connection: Knockouts for 1/2” Conduit
Compliance/Safety
Standards: UL Recognized Class 2/EN60950
LED Capacity
0.10 Watt LEDs: 400 pieces
0.20 Watt LEDs: 200 pieces
0.24 Watt LEDs: 166 pieces
0.40 Watt LEDs: 100 pieces
LED Driver LDR8-80
Tokistar’s LDR8-80 is a dual output Class 2 LED Driver with two independent 40 Watt outputs. It may be operated from a wide range of input voltages. The enclosure is suitable for wet locations.
Part #: LDR8-80

Specifications
Input Range: 100~240 VAC
Frequency Range: 50/60 Hz
Output: 8 VDC (Adjustable +5% / -30%)
Max. Output Current: 10.0A (2 @ 5.0A)
Max. Output Power: 80W (2 @ 40W)
Protection: Overload, Overcurrent, Short Circuit
Operating Temperature: -30ºC to +60ºC
Mechanical Specifications
Dimensions: 3.6” x 11” x 2.25”
Weight: 4 lbs
Enclosure Rating: Nema 3/IP65
Mounting: Flange Mount
Connection: Knockouts for 1/2” Conduit
Compliance/Safety
Standards: UL Recognized Class 2/EN60950
LED Capacity
0.10 Watt LEDs: 800 pieces
0.20 Watt LEDs: 400 pieces
0.24 Watt LEDs: 332 pieces
0.40 Watt LEDs: 200 pieces
In some areas, local codes may require Tapelight be operated from Class 2 Transformers with inherent secondary circuit protection. Primary input is 120 VAC/60 Hz. Transformers with multiple outputs are enclosed within a Rainproof Type 3R Enclosure.
Tokistar’s T12 and T24 Series Transformers come in a wide range of sizes from 100 to 1,200 Watts. Primary input is 120 VAC/60 Hz, and secondary outputs have inherent circuit protection. These transformers are enclosed within a Rainproof Type 3R Enclosure.
Consult factory for transformers with input voltages other than 120VAC @ 60Hz.